The Problem
An interior BC lumber mill had pressure drop in a high-pressure water line powering log sorting equipment. The line ran 150m underground.
Detection Method
Acoustic correlation identified a leak at 87m from pump house. GPR confirmed pipe depth and a failed compression coupling.
Results
1.5m x 1m patch. Coupling replaced. Production speed returned to normal. $25K/week in lost production stopped.